Helios DMB Modulator
| VHF | 174-240 MHz (Band III) | ||
| Input format | NI (G703), NA5376 (G704) or NA5592 (G704) | ||
| Max static delay |
1 s |
||
| Offset delay |
1 s |
||
| Main signal output level |
0 dBm +/-2dB |
||
| Monitoring signal |
-20dB +/-2dB (Relative to main output) |
||
| Output level stability |
+/-0.1dB / 10°c |
||
| Return loss |
>15 dB |
||
| I/Q amplitude unbalanced |
< 0.05% |
||
| I/Q quadrate error |
< 0.05 | ||
| Clock and synchronization |
|||
| 10 MHz reference output |
0 dBm ± 3 dB | ||
| External 10 MHz reference input: |
|||
| Impedance |
50Ω | ||
| Level |
From -5 to +10 dBm | ||
| External 1 pps reference input : |
|||
| Level |
TTL level – 5kΩ | ||
| Min pulse width | 1 µs | ||
Hardware description
| VHF nominal output power | 300 W, 600 W, 1.2 kW, 2.4 kW |
| Frequency range |
174 – 240 MHz Band III |
| Output impedance |
50Ω |
| Output connector |
7/16, 7/8 EIA |
| Efficiency |
Typical : 30% |
| Frequency stability |
1x 10-07 / an |
| Spurious rejection |
> 75dB |
| Liquid cooled |
Redundant hydraulic rack |
| Operating altitude |
< 2900 m (9512 feet) |
| Humidity |
< 90% |
| Electrical power |
Single phase : 204 – 264VAC / 47 – 53 Hz Three phase : 320 – 450VAC / 47 – 53 Hz |
| Type of power line |
Single phase : 3 cables (Ph, neutral, ground) Three phases : 5 cables (Ph1, Ph2, Ph3, neutral, ground) |
| Cos φ |
> 0,90 |
| Temperature range |
5°C – 45°C (Normal operation) 0°C – 50°C (Maximum) |
| Air cooled |
Each chassis has redundant fans |
| Size |
Air cooled transmitters : 42U 19’’ 2100 (H) x 600 (l) x 1000 (L) mm |
| Weight | Helios : ± 14kg Goliath : ± 20kg |